HydroPure RO
Recommended for every home. Final configuration is selected for the household and verified against the water at the tap.
Explore HydroPure RO ↗
Kelowna and Area: (778) 477-6660
Alberta Area: (780) 229-4475
Saskatchewan Area (306) 790-0551
BC
View Royal receives regional water through the Westshore network.
Understanding your local water
View Royal receives regional water through the Westshore network.
The regional treated-water hardness figures below are in the soft-water range. A softener is not the starting recommendation for this municipal supply. If you notice deposits, establish whether they come from hardness, another mineral, or a plumbing issue before choosing equipment.
The 2025 distribution report lists a median chlorine residual of 1.51 mg/L as Cl₂ for the network shown below. CRD uses chloramine to maintain disinfection through its distribution system. If taste is your concern, discuss filtration specifically rated for chloramine reduction and sized for your required flow; a water softener addresses a different problem.
Start with the distribution table for your connected network. The separate treatment-plant table gives regional supply context. Neither is a test of your kitchen tap, and a town name alone does not identify the water at a private-well property.
LiveSmart water-quality summary
This page includes the available dated public measurements below. Hardness is shown in grains per gallon where the source provides enough information to report or convert it. Parameters not present in the published source should not be interpreted as zero.
Conversions of the published hardness results retained on this page. Each row keeps its sample or supply context; these are not additional tests or a single current community average.
| Sample / source context | Sample date | Hardness (mg/L as CaCO₃) | Hardness (GPG) |
|---|---|---|---|
| 2025 median · Juan de Fuca · Westshore · Distribution medians | See the dated source table below | 18.7 | 1.1 GPG |
| 2025 median · CRD Goldstream treated-water results · 2025 | See the dated source table below | 18.1 | 1.1 GPG |
| 2025 minimum · CRD Goldstream treated-water results · 2025 | See the dated source table below | 16 | 0.9 GPG |
| 2025 maximum · CRD Goldstream treated-water results · 2025 | See the dated source table below | 18.5 | 1.1 GPG |
| 2015–2024 median · CRD Goldstream treated-water results · 2025 | See the dated source table below | 16.9 | 1.0 GPG |
| 2015–2024 range · CRD Goldstream treated-water results · 2025 | See the dated source table below | 12-22.1 | 0.7-1.3 GPG |
1 grain per US gallon = 17.118 mg/L as CaCO₃. Original laboratory units, dates, and source links remain with the water results below.
Local water information
View Royal receives regional water through the Westshore network.
2025
Juan de Fuca · Westshore distribution-system results. Shared-system figures apply to the named network, not every property in View Royal.
| Parameter | Unit | 2025 median |
|---|---|---|
| Chlorine residual | mg/L as Cl₂ | 1.51 |
| pH | pH units | 7.6 |
| CaCO3 Hardness | mg/L | 18.7 |
| Alkalinity | mg/L | 18.00 |
| Colour | TCU | 5.0 |
| Conductivity (25ºC) | µS/cm | 57.60 |
| Turbidity | NTU | 0.25 |
Annual and monthly medians are summaries of sampled values, not a guarantee at an individual tap.
CRD · 2025 annual report ↗2025
Juan de Fuca · Westshore distribution-system results. Shared-system figures apply to the named network, not every property in View Royal.
| Month | Bacteria samples | Total coliform >0 | Percent >0 | Positive resamples | Total coliform >10 | E. coli >0 | Turbidity samples | Turbidity >1 NTU | Chlorine median (mg/L as Cl₂) | Temperature median (°C) |
|---|---|---|---|---|---|---|---|---|---|---|
| JAN | 96 | 0 | 0 | 0 | 0 | 0 | 8 | 0 | 1.48 | 7.6 |
| FEB | 85 | 2 | 2.4 | 0 | 0 | 0 | 5 | 0 | 1.58 | 5.7 |
| MAR | 84 | 0 | 0 | 0 | 0 | 0 | 5 | 0 | 1.53 | 7.5 |
| APR | 101 | 0 | 0 | 0 | 0 | 0 | 6 | 0 | 1.47 | 9.6 |
| MAY | 84 | 0 | 0 | 0 | 0 | 0 | 7 | 0 | 1.58 | 12.1 |
| JUN | 85 | 1 | 1.2 | 0 | 1 | 0 | 7 | 1 | 1.48 | 14.5 |
| JUL | 109 | 0 | 0 | 0 | 0 | 0 | 5 | 0 | 1.51 | 17.8 |
| AUG | 92 | 7 | 7.6 | 3 | 1 | 0 | 6 | 0 | 1.53 | 19.7 |
| SEP | 87 | 2 | 2.3 | 0 | 0 | 0 | 5 | 0 | 1.51 | 19.7 |
| OCT | 101 | 0 | 0 | 0 | 0 | 0 | 6 | 0 | 1.46 | 15.6 |
| NOV | 83 | 0 | 0 | 0 | 0 | 0 | 5 | 0 | 1.55 | 11.7 |
| DEC | 85 | 0 | 0 | 0 | 0 | 0 | 5 | 0 | 1.51 | 9.9 |
| Total: | 1092 | 12 | 1.1 | 3 | 2 | 0 | 70 | 1 | 1.51 | 12.6 |
Bacterial concentrations use CFU/100 mL; counts in the table are numbers of samples. Total is the source’s annual summary row. See the report for follow-up investigations and corrective actions.
CRD · 2025 annual report ↗2025 analytical results; historical comparison covers 2015–2024
CRD treated-water results after the Goldstream Water Treatment Plant. These are plant-outlet statistics for the regional supply, not samples from every neighbourhood or home. The 2025 results and the historical 2015–2024 statistics are labelled separately.
| Parameter | Unit | 2025 median | 2025 samples | 2025 minimum | 2025 maximum | 2015–2024 median | 2015–2024 samples | 2015–2024 range |
|---|---|---|---|---|---|---|---|---|
| Alkalinity, Total | mg/L | 17.9 | 11 | 16.7 | 18.9 | 14.7 | 146 | 7.16-23 |
| Carbon, Dissolved Organic | mg/L | 1.9 | 11 | 1.8 | 2.2 | 1.8 | 110 | < 0.5-370 |
| Carbon, Total Organic | mg/L | 1.9 | 11 | 1.6 | 2.5 | 1.80 | 113 | 0.93 - 4.99 |
| Colour, True | TCU | 5 | 53 | 2 | 8 | 3.8 | 509 | < 1.4-17 |
| Conductivity @ 25 C | µS/cm | 56.2 | 53 | 28.7 | 63.7 | 47.7 | 508 | 31.1-98.6 |
| Hardness as CaCO3 | mg/L | 18.1 | 12 | 16 | 18.5 | 16.9 | 140 | 12-22.1 |
| Odour | Odour Profile | 1 | 244 | 1 | 1 | 1 | 2,320 | 1-1 |
| pH | pH units | 7.6 | 51 | 7.08 | 8.41 | 7.22 | 537 | 6.54-8.33 |
| Taste | Flavour Profile | 1 | 221 | 1 | 1 | 1 | 2,308 | 1-1 |
| Total Dissolved Solids | mg/L | 36 | 11 | <10 | 60 | 30 | 113 | <10-78 |
| Total Suspended Solids | mg/L | < 1 | 11 | < 1 | 1.6 | < 1 | 112 | < 1-6 |
| Total Solids | mg/L | 44 | 11 | 30 | 70 | 34 | 109 | < 1-110 |
| Turbidity, Grab Samples | NTU | 0.25 | 245 | 0.15 | 0.9 | 0.28 | 2,395 | 0.1-6.3 |
| Water Temp., Grab Samples | degrees C | 10.3 | 245 | 3.5 | 20.2 | 10.2 | 2,408 | 2.5-21.1 |
| Bromate | mg/L as BrO3 | < 0.0095 | 11 | < 0.0095 | < 0.0095 | < 0.0095 | 41 | < 0.0095-0.011 |
| Bromide | µg/L as Br | 0.056 | 4 | 0.025 | 0.178 | < 0.01 | 37 | 1.8e-005-0.046 |
| Chloride | mg/L as Cl | 4.1 | 3 | 3.8 | 4.9 | 4.3 | 31 | 1-< 10 |
| Chlorate, dissolved | mg/L as ClO2 | < 0.1 | 11 | < 0.1 | 0.18 | < 0.1 | 49 | < 0.1-0.38 |
| Chlorite, dissolved | mg/L as ClO3 | <0.1 | 9.00 | <0.1 | <0.1 | < 0.1 | 10 | < 0.1-< 0.1 |
| Cyanide | mg/L as Cn | < 0.0005 | 4 | < 0.0005 | 0.00052 | < 0.0005 | 32 | < 0.0005-0.00554 |
| Fluoride | mg/L as F | < 0.05 | 4 | < 0.05 | < 0.05 | < 0.05 | 34 | < 0.02-< 0.05 |
| Nitrate, Dissolved | µg/L as N | < 20 | 11 | < 20 | 28 | < 20 | 118 | < 0.02-46 |
| Nitrite, Dissolved | µg/L as N | < 5 | 11 | < 5 | < 5 | < 5 | 118 | < 5-5 |
| Nitrate + Nitrite | µg/L as N | < 20 | 11 | < 20 | 28 | < 20 | 118 | < 20-46 |
| Nitrogen, Ammonia | µg/L as N | 270 | 11 | 220 | 310 | 230 | 113 | 0.11-760 |
| Nitrogen, Total Kjeldahl | µg/L as N | 423 | 11 | 337 | 884 | 381 | 111 | 74-950 |
| Nitrogen, Total | µg/L as N | 429 | 11 | 337 | 884 | 389 | 113 | 104-976 |
| Phosphate, Ortho, Dissolved | µg/L as P | < 1 | 11 | < 1 | 4 | < 3 | 112 | < 1-6.2 |
| Phosphate, Total, Dissolved | µg/L as P | 2 | 11 | < 1 | 2.9 | 2.7 | 113 | < 1-< 30 |
| Phosphate, Total | µg/L as P | 2.8 | 11 | 1.6 | 4.3 | 2.70 | 113 | <1 - 14 |
| Silica | mg/L as SiO2 | 4.6 | 11 | 4.2 | 4.9 | 4.2 | 109 | 2.91-5.5 |
| Silicon | µg/L as Si | 2,030 | 12 | 1,750 | 2,200 | 1,990 | 115 | 1400-2740 |
| Sulphate | mg/L as SO4 | 1.1 | 11 | < 1 | 1.4 | 1.3 | 111 | 0.8-< 10 |
| Sulphide | mg/L as H2S | < 0.0018 | 11 | < 0.0018 | < 0.0018 | < 0.0018 | 46 | < 0.0018-0.027 |
| Sulphur | mg/L as S | < 3 | 12 | < 3 | < 3 | < 3 | 115 | < 3-< 3 |
| Aluminum | µg/L as Al | 12.65 | 12 | 4.3 | 50.6 | 15.7 | 115 | 3.6-67.7 |
| Antimony | µg/L as Sb | < 0.5 | 12 | < 0.5 | < 0.5 | < 0.5 | 115 | < 0.02-< 0.5 |
| Arsenic | µg/L as As | < 0.1 | 12 | < 0.1 | 0.12 | < 0.1 | 115 | 0.04-0.17 |
| Barium | µg/L as Ba | 3.7 | 12 | 2.8 | 4.1 | 3.71 | 115 | 3.3-4.8 |
| Beryllium | µg/L as Be | < 0.1 | 12 | < 0.1 | < 0.1 | < 0.1 | 114 | < 0.01-< 0.1 |
| Bismuth | µg/L as Bi | < 1 | 12 | < 1 | < 1 | < 1 | 115 | < 0.005-< 1 |
| Boron | µg/L as B | < 50 | 12 | < 50 | < 50 | < 50 | 115 | < 10-50 |
| Cadmium | µg/L as Cd | < 0.01 | 12 | < 0.01 | < 0.01 | < 0.01 | 115 | < 0.005-< 0.1 |
| Calcium | mg/L as Ca | 5.105 | 12 | 3.68 | 5.43 | 4.85 | 115 | 4.18-6.82 |
| Chromium | µg/L as Cr | < 1 | 12 | < 1 | < 1 | < 1 | 115 | < 0.1-1.2 |
| Cobalt | µg/L as Co | < 0.2 | 12 | < 0.2 | 0.21 | < 0.2 | 115 | 0.023-< 0.5 |
| Copper | µg/L as Cu | 1.445 | 12 | 1.1 | 3.72 | 6.28 | 115 | 1.03-202 |
| Iron | µg/L as Fe | 27.45 | 12 | 10.7 | 321 | 22 | 115 | 10.4-198 |
| Lead | µg/L as Pb | < 0.2 | 12 | < 0.2 | 0.24 | < 0.2 | 115 | 0.017-1.94 |
| Lithium | µg/L as Li | < 2 | 12 | < 2 | < 2 | < 2 | 77 | < 0.5-13.5 |
| Magnesium | mg/L as Mg | 1.165 | 12 | 1.05 | 2.16 | 1.13 | 115 | 0.146-1.34 |
| Manganese | µg/L as Mn | 7.85 | 12 | 1.8 | 64.2 | 4.5 | 115 | 1.3-51.1 |
| Mercury, Total | µg/L as Hg | < 0.0019 | 11 | < 0.0019 | 0.0021 | < 0.002 | 113 | < 0.0019-< 10 |
| Molybdenum | µg/L as Mo | < 1 | 12 | < 1 | < 1 | < 1 | 115 | < 0.05-< 1 |
| Nickel | mg/L as Ni | < 1 | 12 | < 1 | 3.5 | < 1 | 115 | 0.206-2 |
| Potassium | mg/L as K | 0.1265 | 12 | 0.116 | 0.375 | 0.132 | 115 | 0.111-0.216 |
| Selenium | µg/L as Se | < 0.1 | 12 | < 0.1 | 0.13 | < 0.1 | 115 | < 0.04-0.21 |
| Silver | µg/L as Ag | < 0.02 | 12 | < 0.02 | < 0.02 | < 0.02 | 115 | < 0.005-0.058 |
| Sodium | mg/L as Na | 3.69 | 12 | 3.37 | 7.78 | 1.78 | 115 | 1.39-4.49 |
| Strontium | µg/L as Sr | 15.8 | 12 | 13.6 | 16.9 | 14.7 | 115 | 13-19.7 |
| Thallium | µg/L as Tl | < 0.01 | 12 | < 0.01 | < 0.01 | < 0.01 | 115 | < 0.002-< 0.05 |
| Tin | µg/L as Sn | < 5 | 12 | < 5 | < 5 | < 5 | 115 | < 0.2-< 5 |
| Titanium | µg/L as Ti | < 5 | 12 | < 5 | < 5 | < 5 | 115 | < 0.05-< 5 |
| Uranium | µg/L as U | < 0.1 | 12 | < 0.1 | < 0.1 | < 0.1 | 115 | 0.00 |
| Vanadium | µg/L as V | < 5 | 12 | < 5 | < 5 | < 5 | 115 | <0.2-<5 |
| Zinc | µg/L as Zn | < 5 | 12 | < 5 | < 5 | < 5 | 115 | 0.37-54.1 |
| Zirconium | µg/L as Zr | < 0.1 | 12 | < 0.1 | < 0.1 | < 0.1 | 115 | <0.1-<0.5 |
| Coliforms, Total | CFU/100 mL | < 1 | 307 | < 1 | 2 | <1 | 2,471 | <1 - 200 |
| E. coli | CFU/100 mL | < 1 | 307 | < 1 | < 1 | <1 | 2,472 | <1 - <1 |
| Hetero. Plate Count, 28C (7 day) | CFU/1 mL | < 1 | 242 | < 0.01 | 580 | < 10 | 2,253 | <1 - 770 |
| Total Residual Chlorine | mg/L as Cl2 | 1.98 | 245 | 1.4 | 2.27 | 1.91 | 1,396 | 0.8 - 2.33 |
| Monochloramine | mg/L as Cl2 | 1.88 | 244 | 1.17 | 2.23 | 1.76 | 1,381 | 0-3.09 |
Median is the middle of the measured values. The older comparison is a ten-year summary, not an additional 2025 sample. All result rows in the identified treated-water table are included. Raw-source water and distribution-system tables remain in the full linked report.
Capital Regional District · 2025 annual report ↗These are dated public results for the locations shown, not a current test of your home. “<” means below the stated reporting limit, not zero. The linked reports contain the full results and laboratory notes. Sources checked September 13, 2026. Follow your supplier’s current notices and advisories.
For a home on this soft regional supply, the published hardness does not establish a need for softening. Test the water if the source is uncertain or symptoms do not match the public report.
No. A private well needs its own sampling and analysis. Municipal chlorine and hardness figures should not be used to size well-water treatment.
Identify the concern first, then compare a drinking-tap filter with whole-home filtration. Confirm the specific reduction claim, flow rating and maintenance requirements before choosing a system.
Start with your water
Tell us where you are, what you’re noticing and what space you have. We’ll help you understand the next step.
A LiveSmart recommendation for every home
LiveSmart recommends a HydroPure reverse-osmosis drinking-water system in every home for cleaner, better-tasting water used for drinking, coffee, cooking and ice. Municipal treatment protects the public supply; point-of-use RO provides an additional treatment step at the kitchen tap. Reduction claims depend on the verified system configuration, certification and proper maintenance.
Recommended for every home. Final configuration is selected for the household and verified against the water at the tap.
Explore HydroPure RO ↗When testing confirms hardness, disinfectant taste or odour, iron, manganese, sediment or microbiological concerns, LiveSmart can add the appropriate SoftFlow, CarbonShield, IronShield or UV Guard treatment.
Explore treatment options ↗Community results are a starting point. Household demand, flow, available space and plumbing are checked before equipment is sized and built.
See real installations ↗Friends for Life