top of page

BC

Water results for Metchosin

These results cover Metchosin properties connected to the regional system; confirm your property’s supply.

Understanding your local water

Where your water comes from

These results cover Metchosin properties connected to the regional system; confirm your property’s supply.

Read the utility report ↗

Soft water: start with the actual concern

The regional treated-water hardness figures below are in the soft-water range. A softener is not the starting recommendation for this municipal supply. If you notice deposits, establish whether they come from hardness, another mineral, or a plumbing issue before choosing equipment.

Chloramine, taste and odour

The 2025 distribution report lists a median chlorine residual of 1.51 mg/L as Cl₂ for the network shown below. CRD uses chloramine to maintain disinfection through its distribution system. If taste is your concern, discuss filtration specifically rated for chloramine reduction and sized for your required flow; a water softener addresses a different problem.

Read the utility report ↗

What these numbers tell you

Start with the distribution table for your connected network. The separate treatment-plant table gives regional supply context. Neither is a test of your kitchen tap, and a town name alone does not identify the water at a private-well property.

Local water information

Published water results
for Metchosin.

These results cover Metchosin properties connected to the regional system; confirm your property’s supply.

Juan de Fuca · Westshore · Annual physical and chemical results

2025

Juan de Fuca · Westshore distribution-system results. Shared-system figures apply to the named network, not every property in Metchosin.

Juan de Fuca · Westshore · Distribution medians
ParameterUnit2025 median
Chlorine residualmg/L as Cl₂1.51
pHpH units7.6
CaCO3 Hardnessmg/L18.7
Alkalinitymg/L18.00
ColourTCU5.0
Conductivity (25ºC)µS/cm57.60
TurbidityNTU0.25

Annual and monthly medians are summaries of sampled values, not a guarantee at an individual tap.

CRD · 2025 annual report ↗
Juan de Fuca · Westshore · Monthly monitoring

2025

Juan de Fuca · Westshore distribution-system results. Shared-system figures apply to the named network, not every property in Metchosin.

Juan de Fuca · Westshore · 2025 monthly monitoring
MonthBacteria samplesTotal coliform >0Percent >0Positive resamplesTotal coliform >10E. coli >0Turbidity samplesTurbidity >1 NTUChlorine median (mg/L as Cl₂)Temperature median (°C)
JAN9600000801.487.6
FEB8522.4000501.585.7
MAR8400000501.537.5
APR10100000601.479.6
MAY8400000701.5812.1
JUN8511.2010711.4814.5
JUL10900000501.5117.8
AUG9277.6310601.5319.7
SEP8722.3000501.5119.7
OCT10100000601.4615.6
NOV8300000501.5511.7
DEC8500000501.519.9
Total:1092121.13207011.5112.6

Bacterial concentrations use CFU/100 mL; counts in the table are numbers of samples. Total is the source’s annual summary row. See the report for follow-up investigations and corrective actions.

CRD · 2025 annual report ↗
Goldstream · Treated water after the plant

2025 analytical results; historical comparison covers 2015–2024

CRD treated-water results after the Goldstream Water Treatment Plant. These are plant-outlet statistics for the regional supply, not samples from every neighbourhood or home. The 2025 results and the historical 2015–2024 statistics are labelled separately.

CRD Goldstream treated-water results · 2025
ParameterUnit2025 median2025 samples2025 minimum2025 maximum2015–2024 median2015–2024 samples2015–2024 range
Alkalinity, Totalmg/L17.91116.718.914.71467.16-23
Carbon, Dissolved Organicmg/L1.9111.82.21.8110< 0.5-370
Carbon, Total Organicmg/L1.9111.62.51.801130.93 - 4.99
Colour, TrueTCU553283.8509< 1.4-17
Conductivity @ 25 CµS/cm56.25328.763.747.750831.1-98.6
Hardness as CaCO3mg/L18.1121618.516.914012-22.1
OdourOdour Profile12441112,3201-1
pHpH units7.6517.088.417.225376.54-8.33
TasteFlavour Profile12211112,3081-1
Total Dissolved Solidsmg/L3611<106030113<10-78
Total Suspended Solidsmg/L< 111< 11.6< 1112< 1-6
Total Solidsmg/L4411307034109< 1-110
Turbidity, Grab SamplesNTU0.252450.150.90.282,3950.1-6.3
Water Temp., Grab Samplesdegrees C10.32453.520.210.22,4082.5-21.1
Bromatemg/L as BrO3< 0.009511< 0.0095< 0.0095< 0.009541< 0.0095-0.011
Bromideµg/L as Br0.05640.0250.178< 0.01371.8e-005-0.046
Chloridemg/L as Cl4.133.84.94.3311-< 10
Chlorate, dissolvedmg/L as ClO2< 0.111< 0.10.18< 0.149< 0.1-0.38
Chlorite, dissolvedmg/L as ClO3<0.19.00<0.1<0.1< 0.110< 0.1-< 0.1
Cyanidemg/L as Cn< 0.00054< 0.00050.00052< 0.000532< 0.0005-0.00554
Fluoridemg/L as F< 0.054< 0.05< 0.05< 0.0534< 0.02-< 0.05
Nitrate, Dissolvedµg/L as N< 2011< 2028< 20118< 0.02-46
Nitrite, Dissolvedµg/L as N< 511< 5< 5< 5118< 5-5
Nitrate + Nitriteµg/L as N< 2011< 2028< 20118< 20-46
Nitrogen, Ammoniaµg/L as N270112203102301130.11-760
Nitrogen, Total Kjeldahlµg/L as N4231133788438111174-950
Nitrogen, Totalµg/L as N42911337884389113104-976
Phosphate, Ortho, Dissolvedµg/L as P< 111< 14< 3112< 1-6.2
Phosphate, Total, Dissolvedµg/L as P211< 12.92.7113< 1-< 30
Phosphate, Totalµg/L as P2.8111.64.32.70113<1 - 14
Silicamg/L as SiO24.6114.24.94.21092.91-5.5
Siliconµg/L as Si2,030121,7502,2001,9901151400-2740
Sulphatemg/L as SO41.111< 11.41.31110.8-< 10
Sulphidemg/L as H2S< 0.001811< 0.0018< 0.0018< 0.001846< 0.0018-0.027
Sulphurmg/L as S< 312< 3< 3< 3115< 3-< 3
Aluminumµg/L as Al12.65124.350.615.71153.6-67.7
Antimonyµg/L as Sb< 0.512< 0.5< 0.5< 0.5115< 0.02-< 0.5
Arsenicµg/L as As< 0.112< 0.10.12< 0.11150.04-0.17
Bariumµg/L as Ba3.7122.84.13.711153.3-4.8
Berylliumµg/L as Be< 0.112< 0.1< 0.1< 0.1114< 0.01-< 0.1
Bismuthµg/L as Bi< 112< 1< 1< 1115< 0.005-< 1
Boronµg/L as B< 5012< 50< 50< 50115< 10-50
Cadmiumµg/L as Cd< 0.0112< 0.01< 0.01< 0.01115< 0.005-< 0.1
Calciummg/L as Ca5.105123.685.434.851154.18-6.82
Chromiumµg/L as Cr< 112< 1< 1< 1115< 0.1-1.2
Cobaltµg/L as Co< 0.212< 0.20.21< 0.21150.023-< 0.5
Copperµg/L as Cu1.445121.13.726.281151.03-202
Ironµg/L as Fe27.451210.73212211510.4-198
Leadµg/L as Pb< 0.212< 0.20.24< 0.21150.017-1.94
Lithiumµg/L as Li< 212< 2< 2< 277< 0.5-13.5
Magnesiummg/L as Mg1.165121.052.161.131150.146-1.34
Manganeseµg/L as Mn7.85121.864.24.51151.3-51.1
Mercury, Totalµg/L as Hg< 0.001911< 0.00190.0021< 0.002113< 0.0019-< 10
Molybdenumµg/L as Mo< 112< 1< 1< 1115< 0.05-< 1
Nickelmg/L as Ni< 112< 13.5< 11150.206-2
Potassiummg/L as K0.1265120.1160.3750.1321150.111-0.216
Seleniumµg/L as Se< 0.112< 0.10.13< 0.1115< 0.04-0.21
Silverµg/L as Ag< 0.0212< 0.02< 0.02< 0.02115< 0.005-0.058
Sodiummg/L as Na3.69123.377.781.781151.39-4.49
Strontiumµg/L as Sr15.81213.616.914.711513-19.7
Thalliumµg/L as Tl< 0.0112< 0.01< 0.01< 0.01115< 0.002-< 0.05
Tinµg/L as Sn< 512< 5< 5< 5115< 0.2-< 5
Titaniumµg/L as Ti< 512< 5< 5< 5115< 0.05-< 5
Uraniumµg/L as U< 0.112< 0.1< 0.1< 0.11150.00
Vanadiumµg/L as V< 512< 5< 5< 5115<0.2-<5
Zincµg/L as Zn< 512< 5< 5< 51150.37-54.1
Zirconiumµg/L as Zr< 0.112< 0.1< 0.1< 0.1115<0.1-<0.5
Coliforms, TotalCFU/100 mL< 1307< 12<12,471<1 - 200
E. coliCFU/100 mL< 1307< 1< 1<12,472<1 - <1
Hetero. Plate Count, 28C (7 day)CFU/1 mL< 1242< 0.01580< 102,253<1 - 770
Total Residual Chlorinemg/L as Cl21.982451.42.271.911,3960.8 - 2.33
Monochloraminemg/L as Cl21.882441.172.231.761,3810-3.09

Median is the middle of the measured values. The older comparison is a ten-year summary, not an additional 2025 sample. All result rows in the identified treated-water table are included. Raw-source water and distribution-system tables remain in the full linked report.

Capital Regional District · 2025 annual report ↗

These are dated public results for the locations shown, not a current test of your home. “<” means below the stated reporting limit, not zero. The linked reports contain the full results and laboratory notes. Sources checked September 13, 2026. Follow your supplier’s current notices and advisories.

Water questions in Metchosin

Should I install a water softener here?

For a home on this soft regional supply, the published hardness does not establish a need for softening. Test the water if the source is uncertain or symptoms do not match the public report.

Does the same report apply to a private well?

No. A private well needs its own sampling and analysis. Municipal chlorine and hardness figures should not be used to size well-water treatment.

What if I am concerned about drinking-water taste?

Identify the concern first, then compare a drinking-tap filter with whole-home filtration. Confirm the specific reduction claim, flow rating and maintenance requirements before choosing a system.

Explore carbon filtration ↗

Start with your water

Understand the water
at your own taps.

Tell us where you are, what you’re noticing and what space you have. We’ll help you understand the next step.

bottom of page