top of page

BC

Water results for Maple Ridge

Metro Vancouver lists Maple Ridge among its water-supply member jurisdictions. The tables separate the regional sources; supply routing and blending can change, so no single plant result is assigned to every address.

Understanding your local water

Where your water comes from

Metro Vancouver lists Maple Ridge among its water-supply member jurisdictions. The tables separate the regional sources; supply routing and blending can change, so no single plant result is assigned to every address.

Read the utility report ↗

Hardness and everyday use

The treated-source hardness results are low. A softener is not the starting recommendation for a home on this regional supply. If you see deposits, identify their cause and confirm your water source first.

Read the utility report ↗

Chlorine, taste and filtration

The upstream utility uses chlorine for disinfection. If your goal is to improve taste or odour, compare filtration with a specific chlorine-reduction claim and a suitable flow rating. A water softener addresses hardness; it does not replace that filtration stage.

Read the utility report ↗

Reading the public results

These records give Maple Ridge residents a way to investigate their supplier’s water. Keep the sample location, date, units and result type together when comparing numbers. Local distribution conditions, plumbing and private wells require separate assessment.

Local water information

Published water results
for Maple Ridge.

Metro Vancouver lists Maple Ridge among its water-supply member jurisdictions. The tables separate the regional sources; supply routing and blending can change, so no single plant result is assigned to every address.

Capilano water system · Regional supply

2025 annual averages and treated-water ranges

Regional supply results from the named water system. Source blending and operating conditions vary. These are regional supply statistics, not Vancouver neighbourhood or household samples. Regional context for Maple Ridge: these are the named supplier’s results, not local tap samples.

Greater Vancouver Water District · Capilano · report page 37
ParameterUnitUntreated averageTreated averageTreated range
Alkalinity as CaCO3mg/L3.12117-23
Aluminum Dissolvedµg/L642517-37
Aluminum Totalµg/L1092818-50
Antimony Totalµg/L<0.5<0.5<0.5
Arsenic Totalµg/L<0.5<0.5<0.5
Barium Totalµg/L2.63.02.6 - 3.4
Boron Totalµg/L<10<10<10
Bromateµg/L<10<10<10
Bromideµg/L<10<10<10
Cadmium Totalµg/L<0.2<0.2<0.2
Calcium Totalµg/L1,1807,9107,180 - 8,880
Carbon Organic - Dissolvedmg/L1.70.70.5-1.1
Carbon Organic - Totalmg/L1.80.70.5-1.1
Chlorateµg/L<104220-110
Chloridemg/L<0.62.72.4 - 3.5
Chromium Totalµg/L<0.07<0.05<0.05 - 0.06
Cobalt Totalµg/L<0.5<0.5<0.5
Colour - ApparentACU14<2<2-2
Colour - TrueTCU10<1<1 - 1
Conductivityµmhos/cm115247 - 58
Copper Totalµg/L3.0<0.5<0.5
Cyanide Totalmg/L<0.002<0.002<0.002
Cyanobacterial Toxins – Microcystin – LRµg/L<0.20N/AN/A
1,4-Dioxaneµg/L<1N/AN/A
Formaldehydeµg/LN/A4N/A4N/A4
Fluoridemg/L<0.05<0.05<0.05
Haloacetic Acid 5 (HAA5)µg/L<31610 - 20
Hardness as CaCO3mg/L3.620.518.8 - 22.2
Iron Dissolvedµg/L30<5<5
Iron Totalµg/L89<8<5-15
Lead Totalµg/L<0.5<0.5<0.5
Magnesium Totalµg/L164216157 - 296
Manganese Dissolvedµg/L3.72.00.9 - 4.1
Manganese Totalµg/L4.64.22.0 - 10.2
Mercury Totalµg/L<0.05<0.05<0.05
Molybdenum Totalµg/L<0.5<0.5<0.5
Nickel Totalµg/L<0.5<0.5<0.5
Nitrilotriacetic acid (NTA)µg/L<50N/AN/A
Nitrogen - Ammonia as Nmg/L<0.02<0.02<0.02
Nitrogen - Nitrate as Nmg/L0.070.060.02 - 0.09
Nitrogen - Nitrite as Nmg/L<0.01<0.01<0.01
N-Nitrosodimethylamine (NDMA)ng/L<1.9N/AN/A
pHpH units6.68.37.9 - 8.5
Phenolmg/L<0.004<0.004<0.002 - <0.005
Potassium Totalµg/L156154140 - 166
Residue Total Dissolved (TDS)mg/L143228 - 37
Selenium Totalµg/L<0.5<0.5<0.5
Silica as SiO2mg/L3.53.53.2 - 3.8
Silver Totalµg/L<0.5<0.5<0.5
Sodium Totalµg/L5751,6601,340 - 2,120
Strontiumµg/L5.721.520.5 – 22.4
Total Trihalomethanes (TTHM)µg/L<422.519 - 26
TurbidityNTU0.930.150.07 - 0.40
Uranium Totalµg/L<0.5<0.5<0.5
UV Absorbance 254 nmAbs/cm0.0670.0110.007 - 0.015
Zinc Totalµg/L<3<3<3

Total and dissolved metal measurements are different tests and are retained as separate rows. Follow the current notice for your own water supplier. N/A means not applicable or not available as described in the source. A superscript reference rendered beside N/A points to the original footnote; it is not a measurement. All physical and chemical analytes in this source table are included.

Metro Vancouver · Original 2025 annual report ↗
Seymour water system · Regional supply

2025 annual averages and treated-water ranges

Regional supply results from the named water system. Source blending and operating conditions vary. These are regional supply statistics, not Vancouver neighbourhood or household samples. Regional context for Maple Ridge: these are the named supplier’s results, not local tap samples.

Greater Vancouver Water District · Seymour · report page 38
ParameterUnitUntreated averageTreated averageTreated range
Alkalinity as CaCO3mg/L4.12017 - 23
Aluminum Dissolvedµg/L492515 - 37
Aluminum Totalµg/L762816 - 48
Antimony Totalµg/L<0.5<0.5<0.5
Arsenic Totalµg/L<0.5<0.5<0.5
Barium Totalµg/L3.42.82.4 - 3.0
Boron Totalµg/L<10<10<10
Bromateµg/L<10<10<10
Bromideµg/L<10<10<10
Cadmium Totalµg/L<0.2<0.2<0.2
Calcium Totalµg/L1,6707,8106,930 - 8,760
Carbon Organic - Dissolvedmg/L1.60.70.5 - 1.0
Carbon Organic - Totalmg/L1.60.70.5 - 1.0
Chlorateµg/L<104320 - 110
Chloridemg/L<0.52.82.3 - 3.5
Chromium Totalµg/L<0.05<0.05<0.05
Cobalt Totalµg/L<0.5<0.5<0.5
Colour - ApparentACU14<2<2 - 3
Colour - TrueTCU9<1<1 - 1
Conductivityµmhos/cm145247 - 56
Copper Totalµg/L24.9<0.5<0.5
Cyanide Totalmg/L<0.002<0.002<0.002
Cyanobacterial Toxins – Microcystin – LRµg/L<0.20N/AN/A
1,4-Dioxaneµg/L<1<1<1
Formaldehydeµg/LN/A4N/A4N/A4
Fluoridemg/L<0.05<0.05<0.05
Haloacetic Acid 5 (HAA5)µg/L<3129 - 14
Hardness as CaCO3mg/L4.820.218.1 - 22.1
Iron Dissolvedµg/L59<5<5
Iron Totalµg/L147<9<5 - 20
Lead Totalµg/L<0.5<0.5<0.5
Magnesium Totalµg/L147213154 - 302
Manganese Dissolvedµg/L4.12.60.9 - 5.6
Manganese Totalµg/L5.84.62.4 - 10.6
Mercury Totalµg/L<0.05<0.05<0.05
Molybdenum Totalµg/L<0.5<0.5<0.5
Nickel Totalµg/L<0.5<0.5<0.5
Nitrilotriacetic acid (NTA)µg/L<50<50<50
Nitrogen - Ammonia as Nmg/L<0.02<0.02<0.02
Nitrogen - Nitrate as Nmg/L0.050.060.02 - 0.09
Nitrogen - Nitrite as Nmg/L<0.01<0.01<0.01
N-Nitrosodimethylamine (NDMA)ng/L<1.9<1.9<1.9
pHpH units6.68.17.8 - 8.5
Phenolmg/L<0.004<0.004<0.002 - <0.005
Potassium Totalµg/L156149127 - 165
Residue Total Dissolved (TDS)mg/L153229 - 37
Selenium Totalµg/L<0.5<0.5<0.5
Silica as SiO2mg/L3.43.53.1 - 3.8
Silver Totalµg/L<0.5<0.5<0.5
Sodium Totalµg/L55416501,310 - 2,100
Strontiumµg/L7.220.418.6 – 21.8
Total Trihalomethanes (TTHM)µg/L<418.515 - 20
TurbidityNTU0.560.170.08 - 0.52
Uranium Totalµg/L<0.5<0.5<0.5
UV Absorbance 254 nmAbs/cm0.0610.0110.007 - 0.016
Zinc Totalµg/L<3<3<3

Total and dissolved metal measurements are different tests and are retained as separate rows. Follow the current notice for your own water supplier. N/A means not applicable or not available as described in the source. A superscript reference rendered beside N/A points to the original footnote; it is not a measurement. All physical and chemical analytes in this source table are included.

Metro Vancouver · Original 2025 annual report ↗
Coquitlam water system · Regional supply

2025 annual averages and treated-water ranges

Regional supply results from the named water system. Source blending and operating conditions vary. These are regional supply statistics, not Vancouver neighbourhood or household samples. Regional context for Maple Ridge: these are the named supplier’s results, not local tap samples.

Greater Vancouver Water District · Coquitlam · report page 39
ParameterUnitUntreated averageTreated averageTreated range
Alkalinity as CaCO3mg/L1.9209.5 - 23
Aluminum Dissolvedµg/L556144 - 74
Aluminum Totalµg/L747558 - 85
Antimony Totalµg/L<0.5<0.5<0.5
Arsenic Totalµg/L<0.5<0.5<0.5
Barium Totalµg/L2.62.42.2 - 2.7
Boron Totalµg/L<10<10<10
Bromateµg/L<10<10<10
Bromideµg/L<10<10<10
Cadmium Totalµg/L<0.2<0.2<0.2
Calcium Totalµg/L828824738 - 914
Carbon Organic - Dissolvedmg/L1.61.61.3 - 2.1
Carbon Organic - Totalmg/L1.71.61.3 - 2.1
Chlorateµg/L<1011045 - 160
Chloridemg/L<0.52.32.0 - 2.7
Chromium Totalµg/L<0.05<0.05<0.05
Cobalt Totalµg/L<0.5<0.5<0.5
Colour - ApparentACU12<2<2 - 2
Colour - TrueTCU8<1<1 - 2
Conductivityµmhos/cm84831 - 53
Copper Totalµg/L<0.5<0.5<0.5
Cyanide Totalmg/L<0.002<0.002<0.002
Cyanobacterial Toxins – Microcystin – LRµg/L<0.20N/AN/A
1,4-Dioxaneµg/L<1<1<1
Formaldehydeµg/LN/A1919
Fluoridemg/L<0.05<0.05<0.05
Haloacetic Acid 5 (HAA5)µg/L<375 - 10
Hardness as CaCO3mg/L2.42.42.2 - 2.7
Iron Dissolvedµg/L151710 - 29
Iron Totalµg/L444328 - 97
Lead Totalµg/L<0.5<0.5<0.5
Magnesium Totalµg/L929280 - 102
Manganese Dissolvedµg/L3.42.40.8 - 3.5
Manganese Totalµg/L3.83.22.2 - 4.2
Mercury Totalµg/L<0.05<0.05<0.05
Molybdenum Totalµg/L<0.5<0.5<0.5
Nickel Totalµg/L<0.5<0.5<0.5
Nitrilotriacetic acid (NTA)µg /L<50<50<50
Nitrogen - Ammonia as Nmg/L<0.02<0.02<0.02
Nitrogen - Nitrate as Nmg/L0.070.070.05 - 0.09
Nitrogen - Nitrite as Nmg/L<0.01<0.01<0.01
N-Nitrosodimethylamine (NDMA)ng/L<1.9<1.9<1.9
pHpH units6.38.37.7 - 9.2
Phenolmg/L<0.004<0.004<0.002 - <0.005
Potassium Totalµg/L115114104 - 122
Residue Total Dissolved (TDS)mg/L113330 - 35
Selenium Totalµg/L<0.5<0.5<0.5
Silica as SiO2mg/L2.62.62.5 - 2.8
Silver Totalµg/L<0.5<0.5<0.5
Sodium Totalµg/L46310,1008,910 - 11,200
Strontiumµg/L3.83.83.5 – 4.0
Total Trihalomethanes (TTHM)µg/L<45.54 - 7
TurbidityNTU0.390.330.13 - 2.0
Uranium Totalµg/L<0.5<0.5<0.5
UV Absorbance 254 nmAbs/cm0.0600.0180.015 - 0.031
Zinc Totalµg/L<3<3<3

Total and dissolved metal measurements are different tests and are retained as separate rows. Follow the current notice for your own water supplier. N/A means not applicable or not available as described in the source. A superscript reference rendered beside N/A points to the original footnote; it is not a measurement. All physical and chemical analytes in this source table are included.

Metro Vancouver · Original 2025 annual report ↗

These are dated public results for the locations shown, not a current test of your home. “<” means below the stated reporting limit, not zero. The linked reports contain the full results and laboratory notes. Sources checked September 13, 2026. Follow your supplier’s current notices and advisories.

Water questions in Maple Ridge

Are these samples from my home in Maple Ridge?

No. The location in each table identifies where the utility sampled. Regional results provide context for a connected home, but do not establish the result at your tap.

Which treatment should I consider?

The treated-source hardness results are low. A softener is not the starting recommendation for a home on this regional supply. If you see deposits, identify their cause and confirm your water source first.

What if my property uses a private well?

Confirm the source before using these tables. A private well needs its own water analysis; regional municipal results do not describe it.

Explore carbon filtration ↗

Start with your water

Understand the water
at your own taps.

Tell us where you are, what you’re noticing and what space you have. We’ll help you understand the next step.

bottom of page