LiveSmart
by Neighbourhood Home Protection
Kelowna and Area: (778) 477-6660
Alberta Area: (780) 229-4475
Saskatchewan Area (306) 790-0551
AB
Water results for Fort Saskatchewan
EPCOR’s March 2026 regional map places this community on the Capital Region Northeast network supplied from Edmonton. The utility’s Edmonton results below describe the upstream supply, not samples taken in every local neighbourhood.
Understanding your local water
Where your water comes from
EPCOR’s March 2026 regional map places this community on the Capital Region Northeast network supplied from Edmonton. The utility’s Edmonton results below describe the upstream supply, not samples taken in every local neighbourhood.
Hardness and everyday use
The supplier’s hardness results show that dissolved hardness can be relevant to scale, soap performance and appliance care. Use a test at your home to choose softener capacity and settings; an annual average or regional sample is not an equipment sizing measurement.
Chloramine, taste and filtration
The upstream utility uses chloramine for disinfection. If your goal is to improve taste or odour, compare filtration with a specific chloramine-reduction claim and a suitable flow rating. A water softener addresses hardness; it does not replace that filtration stage.
Reading the public results
These records give Fort Saskatchewan residents a way to investigate their supplier’s water. Keep the sample location, date, units and result type together when comparing numbers. Local distribution conditions, plumbing and private wells require separate assessment.
Local water information
Published water results
for Fort Saskatchewan.
EPCOR’s March 2026 regional map places this community on the Capital Region Northeast network supplied from Edmonton. The utility’s Edmonton results below describe the upstream supply, not samples taken in every local neighbourhood.
Edmonton treatment plants · June and year to date
June 2026; year to date January–June 2026
Combined Edmonton drinking-water treatment-plant statistics. These are not measurements of a specific home or of every regional customer’s distribution system. Regional context for Fort Saskatchewan: these are the named supplier’s results, not local tap samples.
| Parameter | Unit | June samples | June mean | June range | YTD samples | YTD mean | YTD range |
|---|---|---|---|---|---|---|---|
| Alkalinity total | mg CaCO3/L | 60 | 103.9 | 79.0 - 117.0 | 360 | 116.6 | 79.0 - 139.0 |
| Aluminum | mg/L | 2 | 0.044 | 0.039 - 0.049 | 12 | 0.064 | 0.016 - 0.172 |
| Arsenic | mg/L | 2 | 0.0002 | <0.0002 | 12 | 0.0002 | <0.0002 - 0.0002 |
| Bromate Dissolved | mg/L | 10 | 0.006 | <0.005 - 0.010 | 56 | 0.005 | <0.005 - 0.010 |
| Bromodichloromethane | µg/L | 60 | 1.5 | 0.8 - 2.6 | 360 | 1.1 | <0.5 - 2.6 |
| Cadmium | mg/L | 2 | <0.00002 | <0.00002 | 12 | <0.00002 | <0.00002 |
| Calcium Hardness | mg/L CaCO3 | 60 | 113.7 | 103.0 - 132.0 | 360 | 116.9 | 96.0 - 136.0 |
| Chlorate Dissolved | mg/L | 10 | 0.21 | 0.11 - 0.35 | 56 | 0.20 | 0.09 - 0.50 |
| Chloride Dissolved | mg/L | 10 | 8.4 | 6.7 - 9.6 | 56 | 7.5 | 4.8 - 16.2 |
| Chlorine total | mg/L | 60 | 2.07 | 1.72 - 2.24 | 361 | 2.03 | 1.54 - 2.27 |
| Chlorite Dissolved | mg/L | 10 | 0.006 | <0.005 - 0.010 | 56 | 0.008 | <0.005 - 0.136 |
| Chloroform | µg/L | 60 | 22.5 | 11.9 - 35.1 | 360 | 14.2 | 3.8 - 35.1 |
| Chromium | mg/L | 2 | <0.0002 | <0.0002 | 12 | 0.0002 | <0.0002 |
| Colour | TCU | 60 | 0.9 | <0.5 - 1.5 | 360 | 0.8 | <0.5 - 1.7 |
| Conductivity | µS/cm | 10 | 472.3 | 388.0 - 609.0 | 53 | 413.0 | 357.0 - 609.0 |
| Copper | mg/L | 2 | <0.002 | <0.002 | 12 | 0.002 | <0.002 |
| Cryptosporidium | oocysts/100L | 2 | <0.1 | <0.1 | 12 | <0.1 | <0.1 |
| Fluoride | mg/L | 60 | 0.67 | 0.61 - 0.76 | 360 | 0.70 | 0.61 - 0.78 |
| Giardia | cysts/100L | 2 | <0.1 | <0.1 | 12 | <0.1 | <0.1 |
| Haloacetic acids total (HAA5) | µg/L | 2 | 17.7 | 16.0 - 19.3 | 12 | 16.3 | 11.3 - 19.3 |
| Iron | mg/L | 2 | <0.005 | <0.005 | 12 | <0.005 | <0.005 |
| Manganese | mg/L | 2 | <0.002 | <0.002 | 12 | 0.002 | <0.002 - 0.003 |
| Mercury | µg/L | 2 | <0.0050 | <0.0050 | 14 | <0.0050 | <0.0050 |
| Nitrate (as N) dissolved | mg/L | 10 | 0.10 | 0.07 - 0.19 | 56 | 0.08 | 0.02 - 0.22 |
| Nitrite (as N) dissolved | mg/L | 10 | 0.02 | 0.02 | 56 | 0.02 | 0.02 |
| Nitrosodimethylamine, N- [NDMA] | µg/L | 2 | 0.00135 | <0.00108 - 0.00162 | 12 | 0.00108 | <0.0009 - 0.00108 |
| pH | pH units | 60 | 8 | 8 | 360 | 8 | 8 |
| Potassium | mg/L | 2 | 0.9 | 0.8 - 0.9 | 12 | 1.0 | 0.7 - 2.0 |
| Sodium | mg/L | 2 | 13.5 | 12.5 - 14.4 | 12 | 11.4 | 6.6 - 21.6 |
| Sulphate Dissolved | mg/L | 10 | 98.7 | 77.9 - 122.0 | 56 | 77.6 | 62.0 - 122.0 |
| Total Dissolved Solids | mg/L | 2 | 253.00 | 250.00 - 256.00 | 12 | 227.83 | 213.00 - 256.00 |
| Total Hardness | mg/L CaCO3 | 60 | 168.2 | 153.0 - 186.0 | 360 | 176.2 | 146.0 - 204.0 |
| Total Organic Carbon | mg/L | 10 | 2.5 | 1.2 - 3.3 | 52 | 1.6 | 0.9 - 3.3 |
| Trihalomethanes | µg/L | 60 | 24.2 | 13.4 - 37.4 | 360 | 15.5 | 5.3 - 37.4 |
| Turbidity | NTU | 60 | 0.05 | <0.04 - 0.13 | 360 | 0.05 | <0.04 - 0.32 |
| Uranium | mg/L | 2 | <0.0005 | <0.0005 | 12 | 0.0005 | <0.0005 - 0.0006 |
| Zinc | mg/L | 2 | <0.005 | <0.005 | 12 | <0.005 | <0.005 |
Means and ranges are reproduced as reported, including reporting-limit symbols. The original report includes additional parameters and sampling targets.
EPCOR · Original June 2026 summary ↗These are dated public results for the locations shown, not a current test of your home. “<” means below the stated reporting limit, not zero. The linked reports contain the full results and laboratory notes. Sources checked September 13, 2026. Follow your supplier’s current notices and advisories.
Water questions in Fort Saskatchewan
Are these samples from my home in Fort Saskatchewan?
No. The location in each table identifies where the utility sampled. Regional results provide context for a connected home, but do not establish the result at your tap.
Which treatment should I consider?
The supplier’s hardness results show that dissolved hardness can be relevant to scale, soap performance and appliance care. Use a test at your home to choose softener capacity and settings; an annual average or regional sample is not an equipment sizing measurement.
What if my property uses a private well?
Confirm the source before using these tables. A private well needs its own water analysis; regional municipal results do not describe it.
Start with your water
Understand the water
at your own taps.
Tell us where you are, what you’re noticing and what space you have. We’ll help you understand the next step.