HydroPure RO
Recommended for every home. Final configuration is selected for the household and verified against the water at the tap.
Explore HydroPure RO ↗
Kelowna and Area: (778) 477-6660
Alberta Area: (780) 229-4475
Saskatchewan Area (306) 790-0551
BC
Coldstream is served by Greater Vernon Water. The connected system can receive Duteau Creek, Kalamalka Lake and supplemental Antwerp well water, so a single town-wide hardness number would be misleading.
Understanding your local water
Greater Vernon Water serves Vernon and Coldstream. Its interconnected network can move and blend supplies. The July 2026 report says the Antwerp deep well had supplemented Lavington and Coldstream since June 12; this is dated report context, not a claim that every address receives that source today.
The July 17, 2025 PRV 2 sample associated with Duteau Creek reported hardness of 19.7 mg/L as calcium carbonate. The Allenby PS sample associated with Kalamalka Lake reported 186 mg/L. A softener discussion should start with your actual supply and a home test, rather than a single Vernon-area average.
The same two samples recorded free chlorine of 1.49 and 1.41 mg/L. In July 2026, combined distribution free chlorine averaged 1.05 mg/L. If chlorine taste is the concern, consider filtration with an appropriate chlorine-reduction rating and household flow capacity.
The July report includes an Antwerp-area manganese investigation and site-by-site results. Keep those results attached to their named locations. Discolouration at a home should be investigated with the utility and a sample of the actual water before equipment is selected.
LiveSmart water-quality summary
This page includes the available dated public measurements below. Hardness is shown in grains per gallon where the source provides enough information to report or convert it. Parameters not present in the published source should not be interpreted as zero.
Conversions of the published hardness results retained on this page. Each row keeps its sample or supply context; these are not additional tests or a single current community average.
| Sample / source context | Sample date | Hardness (mg/L as CaCO₃) | Hardness (GPG) |
|---|---|---|---|
| Result · Duteau Creek · PRV 2 · comprehensive analysis | See the dated source table below | 19.7 | 1.2 GPG |
| Result · Kalamalka Lake · Allenby PS · comprehensive analysis | See the dated source table below | 186 | 10.9 GPG |
1 grain per US gallon = 17.118 mg/L as CaCO₃. Original laboratory units, dates, and source links remain with the water results below.
Local water information
Coldstream is served by Greater Vernon Water. The connected system can receive Duteau Creek, Kalamalka Lake and supplemental Antwerp well water, so a single town-wide hardness number would be misleading.
July 17, 2025
A sample from the named Greater Vernon Water distribution sampling point, identified by supply source. Not a measurement at every home.
| Parameter | Result | Unit |
|---|---|---|
| ALKALINITY (BICARBONATE, AS CACO3) | 4.7 | mg/L |
| ALKALINITY (CARBONATE, AS CACO3) | <1.0 | mg/L |
| ALKALINITY (HYDROXIDE, AS CACO3) | <1.0 | mg/L |
| ALKALINITY (PHENOLPHTHALEIN, AS CACO3) | <1.0 | mg/L |
| ALKALINITY (TOTAL, AS CACO3) | 4.7 | mg/L |
| ALUMINUM (TOTAL) | 0.278 | mg/L |
| ANTIMONY (TOTAL) | <0.0002 | mg/L |
| ARSENIC (TOTAL) | <0.0005 | mg/L |
| BARIUM (TOTAL) | 0.0132 | mg/L |
| BERYLLIUM (TOTAL) | <0.0001 | mg/L |
| BISMUTH (TOTAL) | <0.0001 | mg/L |
| BORON (TOTAL) | <0.05 | mg/L |
| CADMIUM (TOTAL) | <0.00001 | mg/L |
| CALCIUM (TOTAL) | 5.72 | mg/L |
| CHLORIDE | 18.8 | mg/L |
| CHLORINE (FREE) | 1.49 | mg/L |
| CHLORINE (TOTAL) | 1.72 | mg/L |
| CHROMIUM (TOTAL) | <0.0005 | mg/L |
| COBALT (TOTAL) | <0.0001 | mg/L |
| COLOUR (TRUE) | <5.0 | TCU |
| CONDUCTIVITY | 106 | µS/cm |
| COPPER (TOTAL) | 0.00343 | mg/L |
| CYANIDE (TOTAL) | 0.0043 | mg/L |
| DISSOLVED ORGANIC CARBON | 4.01 | mg/L |
| FLUORIDE | <0.10 | mg/L |
| HARDNESS (TOTAL, AS CACO3) | 19.7 | mg/L |
| IRON (TOTAL) | 0.018 | mg/L |
| LEAD (TOTAL) | <0.0002 | mg/L |
| LITHIUM (TOTAL) | 0.00055 | mg/L |
| MAGNESIUM (TOTAL) | 1.31 | mg/L |
| MANGANESE (TOTAL) | 0.00368 | mg/L |
| MERCURY (TOTAL) | <0.00001 | mg/L |
| MOLYBDENUM (TOTAL) | 0.00023 | mg/L |
| NICKEL (TOTAL) | 0.00055 | mg/L |
| NITRATE | 0.024 | mg N/L |
| NITRITE | <0.01 | mg N/L |
| PHOSPHORUS (TOTAL DISSOLVED) | 0.0096 | mg/L |
| PHOSPHORUS (TOTAL) | 0.0245 | mg/L |
| PH | 6.81 | pH units |
| POTASSIUM (TOTAL) | 0.94 | mg/L |
| SELENIUM (TOTAL) | <0.0005 | mg/L |
| SILICON (TOTAL, AS SI) | 3.1 | mg/L |
| SILVER (TOTAL) | <0.00005 | mg/L |
| SODIUM (TOTAL) | 11.4 | mg/L |
| STRONTIUM (TOTAL) | 0.0382 | mg/L |
| SULFUR (TOTAL) | <3.0 | mg/L |
| SULPHATE | 3.5 | mg/L |
| TELLURIUM (TOTAL) | <0.0005 | mg/L |
| TEMPERATURE | 17.3 | °C |
| THALLIUM (TOTAL) | <0.00002 | mg/L |
| THORIUM (TOTAL) | <0.0001 | mg/L |
| TIN (TOTAL) | <0.0002 | mg/L |
| TITANIUM (TOTAL) | <0.005 | mg/L |
| TOTAL DISSOLVED SOLIDS | 40 | mg/L |
| TOTAL KJELDAHL NITROGEN | 0.177 | mg/L |
| TOTAL ORGANIC CARBON | 4.18 | mg/L |
| TUNGSTEN (TOTAL) | <0.001 | mg/L |
| TURBIDITY | 0.34 | NTU |
| URANIUM (TOTAL) | <0.00002 | mg/L |
| UV TRANSMITTANCE (FILTERED) | 87.2 | % T |
| UV TRANSMITTANCE (UNFILTERED) | 87 | % T |
| VANADIUM (TOTAL) | <0.005 | mg/L |
| ZINC (TOTAL) | 0.0137 | mg/L |
| ZIRCONIUM (TOTAL) | <0.0001 | mg/L |
The less-than sign means the result was below the stated detection limit.
Read the original utility report ↗July 17, 2025
A sample from the named Greater Vernon Water distribution sampling point, identified by supply source. Not a measurement at every home.
| Parameter | Result | Unit |
|---|---|---|
| ALKALINITY (BICARBONATE, AS CACO3) | 142 | mg/L |
| ALKALINITY (CARBONATE, AS CACO3) | <1.0 | mg/L |
| ALKALINITY (HYDROXIDE, AS CACO3) | <1.0 | mg/L |
| ALKALINITY (PHENOLPHTHALEIN, AS CACO3) | <1.0 | mg/L |
| ALKALINITY (TOTAL, AS CACO3) | 142 | mg/L |
| ALUMINUM (TOTAL) | <0.005 | mg/L |
| ANTIMONY (TOTAL) | <0.0002 | mg/L |
| ARSENIC (TOTAL) | 0.0009 | mg/L |
| BARIUM (TOTAL) | 0.0304 | mg/L |
| BERYLLIUM (TOTAL) | <0.0001 | mg/L |
| BISMUTH (TOTAL) | <0.0001 | mg/L |
| BORON (TOTAL) | <0.05 | mg/L |
| CADMIUM (TOTAL) | <0.00001 | mg/L |
| CALCIUM (TOTAL) | 43.3 | mg/L |
| CHLORIDE | 15.4 | mg/L |
| CHLORINE (FREE) | 1.41 | mg/L |
| CHLORINE (TOTAL) | 1.62 | mg/L |
| CHROMIUM (TOTAL) | <0.0005 | mg/L |
| COBALT (TOTAL) | <0.0001 | mg/L |
| COLOUR (TRUE) | <5.0 | TCU |
| CONDUCTIVITY | 448 | µS/cm |
| COPPER (TOTAL) | 0.0147 | mg/L |
| CYANIDE (TOTAL) | <0.002 | mg/L |
| DISSOLVED ORGANIC CARBON | 3.68 | mg/L |
| FLUORIDE | 0.19 | mg/L |
| HARDNESS (TOTAL, AS CACO3) | 186 | mg/L |
| IRON (TOTAL) | <0.01 | mg/L |
| LEAD (TOTAL) | <0.0002 | mg/L |
| LITHIUM (TOTAL) | 0.00656 | mg/L |
| MAGNESIUM (TOTAL) | 18.8 | mg/L |
| MANGANESE (TOTAL) | 0.00143 | mg/L |
| MERCURY (TOTAL) | <0.00001 | mg/L |
| MOLYBDENUM (TOTAL) | 0.00498 | mg/L |
| NICKEL (TOTAL) | <0.0004 | mg/L |
| NITRATE | 0.037 | mg N/L |
| NITRITE | <0.01 | mg N/L |
| PHOSPHORUS (TOTAL DISSOLVED) | 0.024 | mg/L |
| PHOSPHORUS (TOTAL) | 0.0136 | mg/L |
| PH | 8.19 | pH units |
| POTASSIUM (TOTAL) | 5.11 | mg/L |
| SELENIUM (TOTAL) | 0.00093 | mg/L |
| SILICON (TOTAL, AS SI) | 2.5 | mg/L |
| SILVER (TOTAL) | <0.00005 | mg/L |
| SODIUM (TOTAL) | 21.7 | mg/L |
| STRONTIUM (TOTAL) | 0.462 | mg/L |
| SULFUR (TOTAL) | 18.6 | mg/L |
| SULPHATE | 51.5 | mg/L |
| TELLURIUM (TOTAL) | <0.0005 | mg/L |
| TEMPERATURE | 10.8 | °C |
| THALLIUM (TOTAL) | <0.00002 | mg/L |
| THORIUM (TOTAL) | <0.0001 | mg/L |
| TIN (TOTAL) | <0.0002 | mg/L |
| TITANIUM (TOTAL) | <0.005 | mg/L |
| TOTAL DISSOLVED SOLIDS | 230 | mg/L |
| TOTAL KJELDAHL NITROGEN | 0.264 | mg/L |
| TOTAL ORGANIC CARBON | 3.74 | mg/L |
| TUNGSTEN (TOTAL) | <0.001 | mg/L |
| TURBIDITY | 0.78 | NTU |
| URANIUM (TOTAL) | 0.00336 | mg/L |
| UV TRANSMITTANCE (FILTERED) | 92.6 | % T |
| UV TRANSMITTANCE (UNFILTERED) | 91.7 | % T |
| VANADIUM (TOTAL) | <0.005 | mg/L |
| ZINC (TOTAL) | <0.004 | mg/L |
| ZIRCONIUM (TOTAL) | <0.0001 | mg/L |
The less-than sign means the result was below the stated detection limit.
Read the original utility report ↗July 2026
The utility reports the interconnected Duteau, Kalamalka and Antwerp supplies as one combined distribution system. Footnote superscripts are explained below, not appended to the numeric sample counts.
| Parameter | Sampling / laboratory | Unit | Samples | Deviations | Minimum | Maximum | Average |
|---|---|---|---|---|---|---|---|
| Free chlorine | Operator grab samples | mg/L | 117 | 6 | 0.03 | 1.81 | 1.05 |
| Total chlorine | Operator grab samples | mg/L | 117 | — | 0.12 | 2.16 | 1.32 |
| E. coli | RDNO Lab | MPN/100 mL | 125 | — | <1 | <1 | <1 |
| E. coli | CARO | CFU/100 mL | 1 | — | <1 | <1 | <1 |
| Total coliform | RDNO Lab | MPN/100 mL | 125 | 1 | <1 | 118.45 | <1 |
| Turbidity | Operator grab samples | NTU | 118 | — | 0.21 | 2.20 | 0.88 |
The report explains six low-free-chlorine samples and one suspected contaminated sample station, which was cleaned, flushed and resampled below 1 MPN/100 mL. Non-detects use half the reporting limit in average calculations. Three samples per week are duplicated for quality assurance. The CARO E. coli row repeated across the page break is shown once.
Read the original utility report ↗July 2026; individual sample dates shown
Named sites in the Antwerp distribution area, including entries explicitly labelled source or customer house by the utility. These results do not describe all of Vernon or Coldstream.
| Date | Site | Manganese (mg/L) | Utility comment |
|---|---|---|---|
| 2-Jul-26 | Cousins Bay SS | 0.01 | |
| 2-Jul-26 | Giles Drive BO (BO 00074) | 0.09 | |
| 7-Jul-26 | Bessette PRV | 0.07 | |
| 7-Jul-26 | Giles Drive BO (BO 00074) | 0.04 | |
| 7-Jul-26 | Noble Canyon Road SS | 0.00 | |
| 7-Jul-26 | Antwerp Springs PH 2 | 0.09 | Source |
| 8-Jul-26 | Coachwood Crescent | 0.05 | Customer house |
| 8-Jul-26 | Highway 6 SS | 0.14 | |
| 14-Jul-26 | Aberdeen Road SS | 0.03 | |
| 14-Jul-26 | Giles Drive BO (BO 00074) | 0.03 | |
| 14-Jul-26 | Antwerp Springs PH 2 | 0.09 | Source |
| 14-Jul-26 | Brewer Road SS | 0.39 | |
| 14-Jul-26 | Bessette PRV | 0.07 | |
| 16-Jul-26 | Howe Drive | 0.09 | Customer house |
| 21-Jul-26 | Antwerp Springs PH 2 | 0.09 | Source |
| 21-Jul-26 | Springfield Road SS | 0.02 | |
| 21-Jul-26 | Giles Drive BO (BO 00074) | 0.06 | |
| 21-Jul-26 | Bessette PRV | 0.08 | |
| 21-Jul-26 | Aberdeen Road SS | 0.05 | |
| 23-Jul-26 | Dejong Drive | 0.04 | Customer house |
| 28-Jul-26 | Bessette PRV | 0.11 | |
| 28-Jul-26 | Giles Drive BO (BO 00074) | 0.06 | |
| 28-Jul-26 | Aberdeen Road SS | 0.02 | |
| 28-Jul-26 | Antwerp Springs PH 2 | 0.09 | Source |
| 29-Jul-26 | Highway 6 | 0.06 | Customer house |
Original rounding is retained; a printed 0.00 should not be interpreted as proof that manganese is absent.
Read the original utility report ↗These are dated public results for the locations shown, not a current test of your home. “<” means below the stated reporting limit, not zero. The linked reports contain the full results and laboratory notes. Sources checked September 13, 2026. Follow your supplier’s current notices and advisories.
Yes. Source routing, blending and supplemental supply can change. Use the utility’s address information and source-change notices, then confirm conditions at your tap.
No. The sampled Duteau and Kalamalka supplies differ substantially in hardness. Establish which water reaches your home before making that choice.
Start with your water
Tell us where you are, what you’re noticing and what space you have. We’ll help you understand the next step.
A LiveSmart recommendation for every home
LiveSmart recommends a HydroPure reverse-osmosis drinking-water system in every home for cleaner, better-tasting water used for drinking, coffee, cooking and ice. Municipal treatment protects the public supply; point-of-use RO provides an additional treatment step at the kitchen tap. Reduction claims depend on the verified system configuration, certification and proper maintenance.
Recommended for every home. Final configuration is selected for the household and verified against the water at the tap.
Explore HydroPure RO ↗When testing confirms hardness, disinfectant taste or odour, iron, manganese, sediment or microbiological concerns, LiveSmart can add the appropriate SoftFlow, CarbonShield, IronShield or UV Guard treatment.
Explore treatment options ↗Community results are a starting point. Household demand, flow, available space and plumbing are checked before equipment is sized and built.
See real installations ↗Friends for Life