top of page

BC

Water quality information
for Tumbler Ridge.

Use the official utility and municipal sources below to investigate the water serving Tumbler Ridge. Confirm your supplier, request the latest drinking-water analysis and connect it with testing at your home.

From the public supply to your tap

Make the information
useful for your home.

Bring the report for your actual supplier and tell us what you notice: scale, staining, taste, odour or a concern with existing equipment. We connect the available information with an assessment at your property.

  • Confirm the sourceCheck the supplier on your utility account or identify the private well. Nearby properties can use different water systems.
  • Ask for the right recordsLook for the latest drinking-water analysis and the sample location. A treatment-plant result and a distribution-system result describe different points.
  • Plan around your householdWater chemistry, daily demand, flow, plumbing and service access shape the equipment recommendation.

A LiveSmart recommendation for every home

Better drinking water starts with HydroPure RO.

LiveSmart recommends a HydroPure reverse-osmosis drinking-water system in every home for cleaner, better-tasting water used for drinking, coffee, cooking and ice. Municipal treatment protects the public supply; point-of-use RO provides an additional treatment step at the kitchen tap. Reduction claims depend on the verified system configuration, certification and proper maintenance.

HydroPure RO

Recommended for every home. Final configuration is selected for the household and verified against the water at the tap.

Explore HydroPure RO ↗

Whole-home treatment

When testing confirms hardness, disinfectant taste or odour, iron, manganese, sediment or microbiological concerns, LiveSmart can add the appropriate SoftFlow, CarbonShield, IronShield or UV Guard treatment.

Explore treatment options ↗

Built for the home

Community results are a starting point. Household demand, flow, available space and plumbing are checked before equipment is sized and built.

See real installations ↗

Get my LiveSmart water recommendation ↗

Friends for Life

Personal care, through the years.

Your LiveSmart journey continues with commissioning details, My Water Passport, equipment and water-history records, practical support and agreed customer-care follow-up. We help you plan filter changes and service as your home’s needs change.

See the LiveSmart customer journey ↗

Water results · sources reviewed September 25, 2026

Water-quality numbers and their sources.

Tumbler Ridge raw source water — Well 1

June 1, 2022

Historical raw well sample from Table 6-2 of the District’s 2022 annual report, before treatment. These dated source-water results are not current treated household readings. The report contains ambiguous entries for some other raw-water metals; those entries have not been transcribed here. Obtain a newer full chemistry report before selecting or programming treatment.

Tumbler Ridge raw source water — Well 1 · June 1, 2022
ParameterReported resultUnitContext
Hardness19.3 GPGgrains per US gallonConverted from 331 mg/L as CaCO₃.
TDS431mg/L
pH8.01pH units
Turbidity1.31NTU

Read the original utility or laboratory report ↗

Tumbler Ridge raw source water — Well 3

June 1, 2022

Historical raw well sample from Table 6-2 of the District’s 2022 annual report, before treatment. These dated source-water results are not current treated household readings. The report contains ambiguous entries for some other raw-water metals; those entries have not been transcribed here. Obtain a newer full chemistry report before selecting or programming treatment.

Tumbler Ridge raw source water — Well 3 · June 1, 2022
ParameterReported resultUnitContext
Hardness20.2 GPGgrains per US gallonConverted from 346 mg/L as CaCO₃.
TDS373mg/L
pH7.95pH units
Turbidity1.4NTU

Read the original utility or laboratory report ↗

Tumbler Ridge raw source water — Well 7

June 1, 2022

Historical raw well sample from Table 6-2 of the District’s 2022 annual report, before treatment. These dated source-water results are not current treated household readings. The report contains ambiguous entries for some other raw-water metals; those entries have not been transcribed here. Obtain a newer full chemistry report before selecting or programming treatment.

Tumbler Ridge raw source water — Well 7 · June 1, 2022
ParameterReported resultUnitContext
Hardness13.9 GPGgrains per US gallonConverted from 238 mg/L as CaCO₃.
TDS388mg/L
pH8.04pH units
Turbidity7.81NTU

Read the original utility or laboratory report ↗

Tumbler Ridge raw source water — Well 8

June 1, 2022

Historical raw well sample from Table 6-2 of the District’s 2022 annual report, before treatment. These dated source-water results are not current treated household readings. The report contains ambiguous entries for some other raw-water metals; those entries have not been transcribed here. Obtain a newer full chemistry report before selecting or programming treatment.

Tumbler Ridge raw source water — Well 8 · June 1, 2022
ParameterReported resultUnitContext
Hardness24.5 GPGgrains per US gallonConverted from 420 mg/L as CaCO₃.
TDS466mg/L
pH7.91pH units
Turbidity22.8NTU

Read the original utility or laboratory report ↗

Tumbler Ridge treated water — annual on-site monitoring averages

2022 annual averages

Historical on-site monitoring at the water treatment plant. These treated-water annual averages are separate from the June 1 raw well samples above. The reported treated-water maxima were 0.015 mg/L iron and 0.030 mg/L manganese. A current municipal chemistry report remains needed.

Tumbler Ridge treated water — annual on-site monitoring averages · 2022 annual averages
ParameterReported resultUnitContext
Iron0.010mg/LTreated-water annual average, on-site monitoring.
Manganese0.010mg/LTreated-water annual average, on-site monitoring.

Read the original utility or laboratory report ↗

Results apply to the named supply, date and sample location. A “<” result is below the stated laboratory reporting limit, not zero. Hardness conversions use 1 US GPG = 17.118 mg/L as CaCO₃. Parameters without a reported result remain unverified; a missing value is not a zero reading. Source-water results describe water before treatment. Confirm the water at your home before treatment is selected or programmed.

bottom of page