HydroPure RO
Recommended for every home. Final configuration is selected for the household and verified against the water at the tap.
Explore HydroPure RO ↗
Kelowna and Area: (778) 477-6660
Alberta Area: (780) 229-4475
Saskatchewan Area (306) 790-0551
BC
Use the official utility and municipal sources below to investigate the water serving Pemberton. Confirm your supplier, request the latest drinking-water analysis and connect it with testing at your home.
From the public supply to your tap
Bring the report for your actual supplier and tell us what you notice: scale, staining, taste, odour or a concern with existing equipment. We connect the available information with an assessment at your property.
A LiveSmart recommendation for every home
LiveSmart recommends a HydroPure reverse-osmosis drinking-water system in every home for cleaner, better-tasting water used for drinking, coffee, cooking and ice. Municipal treatment protects the public supply; point-of-use RO provides an additional treatment step at the kitchen tap. Reduction claims depend on the verified system configuration, certification and proper maintenance.
Recommended for every home. Final configuration is selected for the household and verified against the water at the tap.
Explore HydroPure RO ↗When testing confirms hardness, disinfectant taste or odour, iron, manganese, sediment or microbiological concerns, LiveSmart can add the appropriate SoftFlow, CarbonShield, IronShield or UV Guard treatment.
Explore treatment options ↗Community results are a starting point. Household demand, flow, available space and plumbing are checked before equipment is sized and built.
See real installations ↗Friends for Life
Your LiveSmart journey continues with commissioning details, My Water Passport, equipment and water-history records, practical support and agreed customer-care follow-up. We help you plan filter changes and service as your home’s needs change.
Water results · sources reviewed September 25, 2026
February 9, 2024
Named municipal sample in Bureau Veritas report C414646. Ridge and Farm Road are distribution locations; Well #2 and Well #3 are separate source-well locations. Results are kept separate and do not imply a single current household reading. The laboratory also flags holding-time exceedances for nitrate-plus-nitrite testing.
| Parameter | Reported result | Unit | Context |
|---|---|---|---|
| Hardness | 2.0 GPG | grains per US gallon | Converted from 34.7 mg/L as CaCO₃. |
| TDS | 100 | mg/L | The laboratory reports that the recommended holding time was exceeded. |
| pH | 7.23 | pH units | |
| Iron | 0.0265 | mg/L | Total-metal result converted from µg/L to mg/L. |
| Manganese | 0.0081 | mg/L | Total-metal result converted from µg/L to mg/L. |
| Sodium | 23.1 | mg/L | |
| Sulphate | 10 | mg/L | |
| Nitrate | 0.209 | mg/L as N | |
| Fluoride | <0.050 | mg/L | |
| Turbidity | 0.11 | NTU | The laboratory reports that the recommended holding time was exceeded. |
February 9, 2024
Named municipal sample in Bureau Veritas report C414646. Ridge and Farm Road are distribution locations; Well #2 and Well #3 are separate source-well locations. Results are kept separate and do not imply a single current household reading. The laboratory also flags holding-time exceedances for nitrate-plus-nitrite testing.
| Parameter | Reported result | Unit | Context |
|---|---|---|---|
| Hardness | 2.0 GPG | grains per US gallon | Converted from 33.6 mg/L as CaCO₃. |
| TDS | 110 | mg/L | The laboratory reports that the recommended holding time was exceeded. |
| pH | 7.26 | pH units | |
| Iron | 0.032 | mg/L | Total-metal result converted from µg/L to mg/L. |
| Manganese | 0.0281 | mg/L | Total-metal result converted from µg/L to mg/L. |
| Sodium | 23.2 | mg/L | |
| Sulphate | 10 | mg/L | |
| Nitrate | 0.211 | mg/L as N | |
| Fluoride | <0.050 | mg/L | |
| Turbidity | 0.3 | NTU | The laboratory reports that the recommended holding time was exceeded. |
February 9, 2024
Named municipal sample in Bureau Veritas report C414646. Ridge and Farm Road are distribution locations; Well #2 and Well #3 are separate source-well locations. Results are kept separate and do not imply a single current household reading. The laboratory also flags holding-time exceedances for nitrate-plus-nitrite testing.
| Parameter | Reported result | Unit | Context |
|---|---|---|---|
| Hardness | 4.2 GPG | grains per US gallon | Converted from 71.3 mg/L as CaCO₃. |
| TDS | 160 | mg/L | The laboratory reports that the recommended holding time was exceeded. |
| pH | 6.65 | pH units | |
| Iron | 0.0716 | mg/L | Total-metal result converted from µg/L to mg/L. |
| Manganese | 0.0938 | mg/L | Total-metal result converted from µg/L to mg/L. |
| Sodium | 14.4 | mg/L | |
| Sulphate | 19 | mg/L | |
| Nitrate | 0.244 | mg/L as N | |
| Fluoride | <0.050 | mg/L | |
| Turbidity | 0.21 | NTU | The laboratory reports that the recommended holding time was exceeded. |
February 9, 2024
Named municipal sample in Bureau Veritas report C414646. Ridge and Farm Road are distribution locations; Well #2 and Well #3 are separate source-well locations. Results are kept separate and do not imply a single current household reading. The laboratory also flags holding-time exceedances for nitrate-plus-nitrite testing.
| Parameter | Reported result | Unit | Context |
|---|---|---|---|
| Hardness | 1.6 GPG | grains per US gallon | Converted from 27.1 mg/L as CaCO₃. |
| TDS | 54 | mg/L | The laboratory reports that the recommended holding time was exceeded. |
| pH | 6.44 | pH units | |
| Iron | 0.0181 | mg/L | Total-metal result converted from µg/L to mg/L. |
| Manganese | 0.039 | mg/L | Total-metal result converted from µg/L to mg/L. |
| Sodium | 4.11 | mg/L | |
| Sulphate | 8.7 | mg/L | |
| Nitrate | 0.203 | mg/L as N | |
| Fluoride | <0.050 | mg/L | |
| Turbidity | 0.24 | NTU | The laboratory reports that the recommended holding time was exceeded. |
Results apply to the named supply, date and sample location. A “<” result is below the stated laboratory reporting limit, not zero. Hardness conversions use 1 US GPG = 17.118 mg/L as CaCO₃. Parameters without a reported result remain unverified; a missing value is not a zero reading. Source-water results describe water before treatment. Confirm the water at your home before treatment is selected or programmed.