HydroPure RO
Recommended for every home. Final configuration is selected for the household and verified against the water at the tap.
Explore HydroPure RO ↗
Kelowna and Area: (778) 477-6660
Alberta Area: (780) 229-4475
Saskatchewan Area (306) 790-0551
BC
Lake Country operates several water systems. Its 2025 annual report provides separate raw-water analyses for six intakes, with markedly different water chemistry.
Understanding your local water
The six raw-water hardness results range from 20.80 to 176.00 mg/L as calcium carbonate. Identify the actual supply system before comparing the data. Raw-water chemistry gives source context and must not be read as a statement about water after treatment.
Confirm the supplier and sample location before comparing the figures. We use the public record alongside testing at your property, household demand and available plumbing to plan treatment and future care.
LiveSmart water-quality summary
This page includes the available dated public measurements below. Hardness is shown in grains per gallon where the source provides enough information to report or convert it. Parameters not present in the published source should not be interpreted as zero.
Water results · sources reviewed September 25, 2026
2025-08-08
Raw intake water before treatment, as identified in Appendix C. Each intake is a separate supply; these are not treated household readings.
| Parameter | Reported result | Unit | Context |
|---|---|---|---|
| Fluoride | 0.13 | mg/L | |
| Nitrate as N | 0.04 | mg/L | |
| Sulphate | 3.50 | mg/L | |
| Iron (total) | 0.10 | mg/L | |
| Manganese (total) | 0.00732 | mg/L | |
| Sodium (total) | 2.62 | mg/L |
2025-08-07
Raw intake water before treatment, as identified in Appendix C. Each intake is a separate supply; these are not treated household readings.
| Parameter | Reported result | Unit | Context |
|---|---|---|---|
| Fluoride | <0.10 | mg/L | |
| Nitrate as N | 0.04 | mg/L | |
| Sulphate | 2.10 | mg/L | |
| Iron (total) | 0.13 | mg/L | |
| Manganese (total) | 0.01300 | mg/L | |
| Sodium (total) | 2.23 | mg/L |
2025-08-07
Raw intake water before treatment, as identified in Appendix C. Each intake is a separate supply; these are not treated household readings.
| Parameter | Reported result | Unit | Context |
|---|---|---|---|
| Fluoride | 0.18 | mg/L | |
| Nitrate as N | 0.03 | mg/L | |
| Sulphate | 50.00 | mg/L | |
| Iron (total) | <0.01 | mg/L | |
| Manganese (total) | 0.00249 | mg/L | |
| Sodium (total) | 18.90 | mg/L |
2025-08-05
Raw intake water before treatment, as identified in Appendix C. Each intake is a separate supply; these are not treated household readings.
| Parameter | Reported result | Unit | Context |
|---|---|---|---|
| Fluoride | 0.14 | mg/L | |
| Nitrate as N | 0.03 | mg/L | |
| Sulphate | 27.80 | mg/L | |
| Iron (total) | <0.01 | mg/L | |
| Manganese (total) | 0.00103 | mg/L | |
| Sodium (total) | 12.40 | mg/L |
2025-08-05
Raw intake water before treatment, as identified in Appendix C. Each intake is a separate supply; these are not treated household readings.
| Parameter | Reported result | Unit | Context |
|---|---|---|---|
| Fluoride | 0.10 | mg/L | |
| Nitrate as N | 0.04 | mg/L | |
| Sulphate | 29.90 | mg/L | |
| Iron (total) | 0.01 | mg/L | |
| Manganese (total) | 0.00146 | mg/L | |
| Sodium (total) | 12.30 | mg/L |
2025-08-06
Raw intake water before treatment, as identified in Appendix C. Each intake is a separate supply; these are not treated household readings.
| Parameter | Reported result | Unit | Context |
|---|---|---|---|
| Fluoride | 0.14 | mg/L | |
| Nitrate as N | 0.06 | mg/L | |
| Sulphate | 29.70 | mg/L | |
| Iron (total) | <0.01 | mg/L | |
| Manganese (total) | 0.00112 | mg/L | |
| Sodium (total) | 12.10 | mg/L |
Results apply to the named supply, date and sample location. A “<” result is below the stated laboratory reporting limit, not zero. Hardness conversions use 1 US GPG = 17.118 mg/L as CaCO₃. Parameters without a reported result remain unverified; a missing value is not a zero reading. Source-water results describe water before treatment. Confirm the water at your home before treatment is selected or programmed.
Conversions of the published hardness results retained on this page. Each row keeps its sample or supply context; these are not additional tests or a single current community average.
| Sample / source context | Sample date | Hardness (mg/L as CaCO₃) | Hardness (GPG) |
|---|---|---|---|
| Vernon Creek / Beaver · Six raw-water intakes · before treatment · August 5–8, 2025 | See the dated source table below | 31.60 | 1.8 GPG |
| Oyama Creek · Six raw-water intakes · before treatment · August 5–8, 2025 | See the dated source table below | 20.80 | 1.2 GPG |
| Kalamalka · Six raw-water intakes · before treatment · August 5–8, 2025 | See the dated source table below | 176.00 | 10.3 GPG |
| Coral Beach · Six raw-water intakes · before treatment · August 5–8, 2025 | See the dated source table below | 130.00 | 7.6 GPG |
| Lake Pine · Six raw-water intakes · before treatment · August 5–8, 2025 | See the dated source table below | 128.00 | 7.5 GPG |
| Okanagan Lake · Six raw-water intakes · before treatment · August 5–8, 2025 | See the dated source table below | 129.00 | 7.5 GPG |
1 grain per US gallon = 17.118 mg/L as CaCO₃. Original laboratory units, dates, and source links remain with the water results below.
Local water information
Lake Country operates several water systems. Its 2025 annual report provides separate raw-water analyses for six intakes, with markedly different water chemistry.
August 5–8, 2025
Appendix C: Raw Comprehensive Test Results. Dates: Vernon Creek August 8; Oyama Creek August 7; Kalamalka August 7; Coral Beach August 5; Lake Pine August 5; Okanagan Lake August 6. These are raw source-water samples, not finished drinking water or household tap samples.
| Parameter | Unit | Vernon Creek / Beaver | Oyama Creek | Kalamalka | Coral Beach | Lake Pine | Okanagan Lake |
|---|---|---|---|---|---|---|---|
| Hardness | mg/L as CaCO3 | 31.60 | 20.80 | 176.00 | 130.00 | 128.00 | 129.00 |
| Total dissolved solids | mg/L | 37.40 | 27.50 | 236.00 | 162.00 | 164.00 | 162.00 |
| pH | pH units | 6.67 | 7.67 | 7.98 | 7.74 | 7.70 | 7.47 |
| Turbidity | NTU | 0.83 | 0.37 | 0.69 | 0.44 | 0.35 | 0.34 |
| Total alkalinity | mg/L | 29.90 | 23.90 | 151.00 | 110.00 | 112.00 | 109.00 |
| Conductivity | µS/cm | 73.20 | 51.90 | 437.00 | 304.00 | 309.00 | 293.00 |
Selected results are reproduced here. Read the original report for the complete analysis, methods and laboratory qualifiers.
2025 Water Operations Annual Report ↗These are dated public results for the locations shown, not a current test of your home. “<” means below the stated reporting limit, not zero. The linked reports contain the full results and laboratory notes. Sources checked September 15, 2026. Follow your supplier’s current notices and advisories.
Start with your water
Tell us where you are, what you’re noticing and what space you have. We’ll help you understand the next step.
A LiveSmart recommendation for every home
LiveSmart recommends a HydroPure reverse-osmosis drinking-water system in every home for cleaner, better-tasting water used for drinking, coffee, cooking and ice. Municipal treatment protects the public supply; point-of-use RO provides an additional treatment step at the kitchen tap. Reduction claims depend on the verified system configuration, certification and proper maintenance.
Recommended for every home. Final configuration is selected for the household and verified against the water at the tap.
Explore HydroPure RO ↗When testing confirms hardness, disinfectant taste or odour, iron, manganese, sediment or microbiological concerns, LiveSmart can add the appropriate SoftFlow, CarbonShield, IronShield or UV Guard treatment.
Explore treatment options ↗Community results are a starting point. Household demand, flow, available space and plumbing are checked before equipment is sized and built.
See real installations ↗Friends for Life