top of page

BC

Water results for Creston

Creston’s 2025 report publishes April and October analyses for Crawford Hill Reservoir and two wells. The differences between those locations matter when reading the results.

Understanding your local water

Reading the local results

The well and reservoir hardness results differ substantially, so one “Creston hardness” number would hide useful information. Confirm which source serves the property and test at the tap before choosing a softener or its settings.

Read the utility report ↗

Connect the report with your home

Confirm the supplier and sample location before comparing the figures. We use the public record alongside testing at your property, household demand and available plumbing to plan treatment and future care.

LiveSmart water-quality summary

Published water-quality measurements.

This page includes the available dated public measurements below. Hardness is shown in grains per gallon where the source provides enough information to report or convert it. Parameters not present in the published source should not be interpreted as zero.

Water results · sources reviewed September 25, 2026

Additional published water measurements.

Crawford Hill Reservoir · additional laboratory chemistry

April 2025

Municipal potable-water analysis at the named reservoir or well. These sampling locations and the two sampling months are separate results.

Crawford Hill Reservoir · additional laboratory chemistry · April 2025
ParameterReported resultUnitContext
Fluoride<0.10mg/L
Nitrate as N0.084mg/L
Sulphate5.2mg/L
Iron (total)<0.01mg/L
Manganese (total)<0.00020mg/L
Sodium (total)2.76mg/L

Read the original utility or laboratory report ↗

Well #2 · additional laboratory chemistry

April 2025

Municipal potable-water analysis at the named reservoir or well. These sampling locations and the two sampling months are separate results.

Well #2 · additional laboratory chemistry · April 2025
ParameterReported resultUnitContext
Fluoride<0.10mg/L
Nitrate as N0.172mg/L
Sulphate5.4mg/L
Iron (total)0.046mg/L
Manganese (total)0.00029mg/L
Sodium (total)5.08mg/L

Read the original utility or laboratory report ↗

Well #3 · additional laboratory chemistry

April 2025

Municipal potable-water analysis at the named reservoir or well. These sampling locations and the two sampling months are separate results.

Well #3 · additional laboratory chemistry · April 2025
ParameterReported resultUnitContext
Fluoride<0.10mg/L
Nitrate as N1.33mg/L
Sulphate29.6mg/L
Iron (total)0.776mg/L
Manganese (total)0.00927mg/L
Sodium (total)20.9mg/L

Read the original utility or laboratory report ↗

Crawford Hill Reservoir · additional laboratory chemistry

October 2025

Municipal potable-water analysis at the named reservoir or well. These sampling locations and the two sampling months are separate results.

Crawford Hill Reservoir · additional laboratory chemistry · October 2025
ParameterReported resultUnitContext
Fluoride<0.10mg/L
Nitrate as N<0.010mg/L
Sulphate5.9mg/L
Iron (total)<0.01mg/L
Manganese (total)<0.00020mg/L
Sodium (total)2.48mg/L

Read the original utility or laboratory report ↗

Well #2 · additional laboratory chemistry

October 2025

Municipal potable-water analysis at the named reservoir or well. These sampling locations and the two sampling months are separate results.

Well #2 · additional laboratory chemistry · October 2025
ParameterReported resultUnitContext
Fluoride<0.10mg/L
Nitrate as N0.220mg/L
Sulphate5.6mg/L
Iron (total)<0.01mg/L
Manganese (total)<0.00020mg/L
Sodium (total)5.08mg/L

Read the original utility or laboratory report ↗

Well #3 · additional laboratory chemistry

October 2025

Municipal potable-water analysis at the named reservoir or well. These sampling locations and the two sampling months are separate results.

Well #3 · additional laboratory chemistry · October 2025
ParameterReported resultUnitContext
Fluoride<0.10mg/L
Nitrate as N0.079mg/L
Sulphate27.8mg/L
Iron (total)0.320mg/L
Manganese (total)0.00530mg/L
Sodium (total)22.1mg/L

Read the original utility or laboratory report ↗

Results apply to the named supply, date and sample location. A “<” result is below the stated laboratory reporting limit, not zero. Hardness conversions use 1 US GPG = 17.118 mg/L as CaCO₃. Parameters without a reported result remain unverified; a missing value is not a zero reading. Source-water results describe water before treatment. Confirm the water at your home before treatment is selected or programmed.

Hardness in grains per gallon.

Conversions of the published hardness results retained on this page. Each row keeps its sample or supply context; these are not additional tests or a single current community average.

View hardness results in GPG
Sample / source contextSample dateHardness (mg/L as CaCO₃)Hardness (GPG)
Crawford Hill Reservoir · Crawford Hill Reservoir, Well #2 and Well #3 · April 2025See the dated source table below29.01.7 GPG
Well #2 · Crawford Hill Reservoir, Well #2 and Well #3 · April 2025See the dated source table below55.63.2 GPG
Well #3 · Crawford Hill Reservoir, Well #2 and Well #3 · April 2025See the dated source table below24114.1 GPG
Crawford Hill Reservoir · Crawford Hill Reservoir, Well #2 and Well #3 · October 2025See the dated source table below44.22.6 GPG
Well #2 · Crawford Hill Reservoir, Well #2 and Well #3 · October 2025See the dated source table below593.4 GPG
Well #3 · Crawford Hill Reservoir, Well #2 and Well #3 · October 2025See the dated source table below26415.4 GPG

1 grain per US gallon = 17.118 mg/L as CaCO₃. Original laboratory units, dates, and source links remain with the water results below.

Local water information

Published water results
for Creston.

Creston’s 2025 report publishes April and October analyses for Crawford Hill Reservoir and two wells. The differences between those locations matter when reading the results.

Crawford Hill Reservoir, Well #2 and Well #3

April 2025

Town of Creston Potable Water Analyses. The three named sampling points are retained separately; a well result does not establish the blend or result at a home.

Crawford Hill Reservoir, Well #2 and Well #3 · April 2025
ParameterUnitCrawford Hill ReservoirWell #2Well #3
Hardnessmg/L as CaCO329.055.6241
Total dissolved solidsmg/L3262303
pHpH units7.007.147.60
TurbidityNTU0.15<0.103.63
Total alkalinitymg/L as CaCO334.557.9218

Selected results are reproduced here. Read the original report for the complete analysis, methods and laboratory qualifiers.

View the 2025 Annual Water Report ↗
Crawford Hill Reservoir, Well #2 and Well #3

October 2025

Town of Creston Potable Water Analyses. The three named sampling points are retained separately; a well result does not establish the blend or result at a home.

Crawford Hill Reservoir, Well #2 and Well #3 · October 2025
ParameterUnitCrawford Hill ReservoirWell #2Well #3
Hardnessmg/L as CaCO344.259264
Total dissolved solidsmg/L5969340
pHpH units6.656.757.40
TurbidityNTU<0.100.121.08
Total alkalinitymg/L as CaCO354.369.6240

Selected results are reproduced here. Read the original report for the complete analysis, methods and laboratory qualifiers.

View the 2025 Annual Water Report ↗

These are dated public results for the locations shown, not a current test of your home. “<” means below the stated reporting limit, not zero. The linked reports contain the full results and laboratory notes. Sources checked September 15, 2026. Follow your supplier’s current notices and advisories.

Start with your water

Understand the water
at your own taps.

Tell us where you are, what you’re noticing and what space you have. We’ll help you understand the next step.

A LiveSmart recommendation for every home

Better drinking water starts with HydroPure RO.

LiveSmart recommends a HydroPure reverse-osmosis drinking-water system in every home for cleaner, better-tasting water used for drinking, coffee, cooking and ice. Municipal treatment protects the public supply; point-of-use RO provides an additional treatment step at the kitchen tap. Reduction claims depend on the verified system configuration, certification and proper maintenance.

HydroPure RO

Recommended for every home. Final configuration is selected for the household and verified against the water at the tap.

Explore HydroPure RO ↗

Whole-home treatment

When testing confirms hardness, disinfectant taste or odour, iron, manganese, sediment or microbiological concerns, LiveSmart can add the appropriate SoftFlow, CarbonShield, IronShield or UV Guard treatment.

Explore treatment options ↗

Built for the home

Community results are a starting point. Household demand, flow, available space and plumbing are checked before equipment is sized and built.

See real installations ↗

Get my LiveSmart water recommendation ↗

Friends for Life

Personal care, through the years.

Your LiveSmart journey continues with commissioning details, My Water Passport, equipment and water-history records, practical support and agreed customer-care follow-up. We help you plan filter changes and service as your home’s needs change.

See the LiveSmart customer journey ↗

bottom of page