HydroPure RO
Recommended for every home. Final configuration is selected for the household and verified against the water at the tap.
Explore HydroPure RO ↗
Kelowna and Area: (778) 477-6660
Alberta Area: (780) 229-4475
Saskatchewan Area (306) 790-0551
BC
Chetwynd’s 2025 annual water report includes a detailed water-treatment-plant sample collected on September 23, 2025.
Understanding your local water
The report distinguishes dissolved hardness from hardness calculated using total calcium and magnesium. Keep those definitions with the figures when comparing another laboratory report or planning treatment.
Confirm the supplier and sample location before comparing the figures. We use the public record alongside testing at your property, household demand and available plumbing to plan treatment and future care.
LiveSmart water-quality summary
This page includes the available dated public measurements below. Hardness is shown in grains per gallon where the source provides enough information to report or convert it. Parameters not present in the published source should not be interpreted as zero.
Water results · sources reviewed September 25, 2026
2025-09-23 08:00
Appendix A sampling point as reported. The pond, skid and plant are separate locations; pond results are not finished-water readings.
| Parameter | Reported result | Unit | Context |
|---|---|---|---|
| Iron (total) | <0.010 | mg/L | |
| Manganese (total) | 0.00068 | mg/L | |
| Sodium (total) | 7.63 | mg/L |
2025-09-23 08:15
Appendix A sampling point as reported. The pond, skid and plant are separate locations; pond results are not finished-water readings.
| Parameter | Reported result | Unit | Context |
|---|---|---|---|
| Iron (total) | <0.010 | mg/L | |
| Manganese (total) | 0.00074 | mg/L | |
| Sodium (total) | 2.92 | mg/L |
2025-09-23 08:30
Appendix A sampling point as reported. The pond, skid and plant are separate locations; pond results are not finished-water readings.
| Parameter | Reported result | Unit | Context |
|---|---|---|---|
| Iron (total) | 0.038 | mg/L | |
| Manganese (total) | 0.0120 | mg/L | |
| Sodium (total) | 2.85 | mg/L |
Results apply to the named supply, date and sample location. A “<” result is below the stated laboratory reporting limit, not zero. Hardness conversions use 1 US GPG = 17.118 mg/L as CaCO₃. Parameters without a reported result remain unverified; a missing value is not a zero reading. Source-water results describe water before treatment. Confirm the water at your home before treatment is selected or programmed.
Conversions of the published hardness results retained on this page. Each row keeps its sample or supply context; these are not additional tests or a single current community average.
| Sample / source context | Sample date | Hardness (mg/L as CaCO₃) | Hardness (GPG) |
|---|---|---|---|
| Reported value · Water Treatment Plant · 08:00 sample · September 23, 2025 | See the dated source table below | 105 | 6.1 GPG |
| Reported value · Water Treatment Plant · 08:00 sample · September 23, 2025 | See the dated source table below | 107 | 6.3 GPG |
1 grain per US gallon = 17.118 mg/L as CaCO₃. Original laboratory units, dates, and source links remain with the water results below.
Local water information
Chetwynd’s 2025 annual water report includes a detailed water-treatment-plant sample collected on September 23, 2025.
September 23, 2025
Appendix A, Water Chemistry Data. Values here are from the Water Treatment Plant column; Skid B, pond and lowlift samples are separate locations.
| Parameter | Unit | Reported value |
|---|---|---|
| Dissolved hardness | mg/L as CaCO3 | 105 |
| Hardness from total calcium and magnesium | mg/L as CaCO3 | 107 |
| Total dissolved solids | mg/L | 164 |
| Total alkalinity | mg/L as CaCO3 | 102 |
| Conductivity | µS/cm | 234 |
| pH | pH units | 8.51 |
| Turbidity | NTU | <0.10 |
| Chloride | mg/L | 9.35 |
| Fluoride | mg/L | 0.086 |
| Nitrate as N | mg/L | <0.0050 |
| Sulfate | mg/L | 19.2 |
Selected results are reproduced here. Read the original report for the complete analysis, methods and laboratory qualifiers.
2025- DOC Annual Water Report – Northern Health ↗These are dated public results for the locations shown, not a current test of your home. “<” means below the stated reporting limit, not zero. The linked reports contain the full results and laboratory notes. Sources checked September 15, 2026. Follow your supplier’s current notices and advisories.
Start with your water
Tell us where you are, what you’re noticing and what space you have. We’ll help you understand the next step.
A LiveSmart recommendation for every home
LiveSmart recommends a HydroPure reverse-osmosis drinking-water system in every home for cleaner, better-tasting water used for drinking, coffee, cooking and ice. Municipal treatment protects the public supply; point-of-use RO provides an additional treatment step at the kitchen tap. Reduction claims depend on the verified system configuration, certification and proper maintenance.
Recommended for every home. Final configuration is selected for the household and verified against the water at the tap.
Explore HydroPure RO ↗When testing confirms hardness, disinfectant taste or odour, iron, manganese, sediment or microbiological concerns, LiveSmart can add the appropriate SoftFlow, CarbonShield, IronShield or UV Guard treatment.
Explore treatment options ↗Community results are a starting point. Household demand, flow, available space and plumbing are checked before equipment is sized and built.
See real installations ↗Friends for Life